Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Spine Deform ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38578598

RESUMEN

PURPOSE: To evaluate proximal junctional biomechanics of a MLSS relative to traditional pedicle screw fixation at the proximal extent of T10-pelvis posterior instrumentation constructs (T10-p PSF). METHODS: A previously validated three-dimensional osseoligamentous spinopelvic finite element (FE) model was used to compare proximal junctional range-of-motion (ROM), vertebral body stresses, and discal biomechanics between two groups: (1) T10-p with a T10-11 MLSS ("T10-11 MLSS") and (2) T10-p with a traditional T10 pedicle screw ("Traditional T10-PS"). RESULTS: The T10-11 MLSS had a 5% decrease in T9 cortical bone stress compared to Traditional T10-PS. Conversely, the T10 and T11 bone stresses increased by 46% and 98%, respectively, with T10-11 MLSS compared to Traditional T10-PS. Annular stresses and intradiscal pressures (IDP) were similar at T9-T10 between constructs. At the T10-11 disc, T10-11 MLSS decreased annular stresses by 29% and IDP by 48% compared to Traditional T10-PS. Adjacent ROM (T8-9 & T9-10) were similar between T10-11 MLSS and Traditional T10-PS. T10-11 MLSS had 39% greater ROM at T10-11 and 23% less ROM at T11-12 compared to Traditional T10-PS. CONCLUSIONS: In this FE analysis, a T10-11 MLSS at the proximal extent of T10-pelvis posterior instrumentation resulted in increased T10 and T11 cortical bone stresses, decreased discal annular stress and IDP and increased ROM at T10-11, and no change in ROM at the adjacent level. Given the complex and multifactorial nature of proximal junctional kyphosis, these results require additional biomechanical and clinical evaluations to determine the clinical utility of MLSS on the proximal junctions of thoracolumbar posterior instrumented fusions.

2.
Spine Deform ; 12(2): 313-322, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38032447

RESUMEN

PURPOSE: To develop and validate a finite element (FE) model of a sacral pedicle subtraction osteotomy (S1-PSO) and to compare biomechanical properties of various multi-rod configurations to stabilize S1-PSOs. METHODS: A previously validated FE spinopelvic model was used to develop a 30° PSO at the sacrum. Five multi-rod techniques spanning the S1-PSO were made using 4 iliac screws and a variety of primary rods (PR) and accessory rods (AR; lateral: Lat-AR or medial: Med-AR). All constructs, except one, utilized a horizontal rod (HR) connecting the iliac bolts to which PRs and Med-ARs were connected. Lat-ARs were connected to proximal iliac bolts. The simulation was performed in two steps with the acetabula fixed. For each model, PSO ROM and maximum stress on the PRs, ARs, and HRs were recorded and compared. The maximum stress on the L5-S1 disc and the PSO forces were captured and compared. RESULTS: Highest PSO ROMs were observed for 4-Rods (HR + 2 Med-AR). Constructs consisting of 5-Rods (HR + 2 Lat-ARs + 1 Med-AR) and 6-Rods (HR + 2 Lat-AR + 2 Med-AR) had the lowest PSO ROM. The least stress on the primary rods was seen with 6-Rods, followed by 5-Rods and 4-Rods (HR + 2 Lat-ARs). Lowest PSO forces and lowest L5-S1 disc stresses were observed for 4-Rod (Lat-AR), 5-Rod, and 6-Rod constructs, while 4-Rods (HR + Med-AR) had the highest. CONCLUSION: In this first FE analysis of an S1-PSO, the 4-Rod construct (HR + Med-AR) created the least rigid environment and highest PSO forces anteriorly. While 5- and 6-Rods created the stiffest constructs and lowest stresses on the primary rods, it also jeopardized load transfer to the anterior column, which may not be favorable for healing anteriorly. A balance between the construct's rigidity and anterior load sharing is essential.


Asunto(s)
Vértebras Lumbares , Osteotomía , Humanos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Osteotomía/métodos , Rango del Movimiento Articular , Vértebras Lumbares/cirugía
3.
Spine Deform ; 11(3): 535-543, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36484928

RESUMEN

PURPOSE: To assess biomechanics of a lumbar PSO stabilized with different multi-rod constructs (4-, 5-, 6-rods) using satellite and accessory rods. METHODS: A validated spinopelvic finite element model with a L3 PSO was used to evaluate the following constructs: 2 primary rods T10-pelvis ("Control"), two satellite rods (4-rod), two satellite rods + one accessory rod (5-rod), or two satellite rods + two accessory rods (6-rod). Data recorded included: ROM T10-S1 and L2-L4, von Mises stresses on primary, satellite, and accessory rods, factor of safety yield stress, and force across the PSO surfaces. Percent differences relative to Control were calculated. RESULTS: Compared to Control, 4-rods increased PSO flexion and extension. Lower PSO ROMs were observed for 5- and 6-rods compared to 4-rods. However, 4-rod (348.6 N) and 5-rod (343.2 N) showed higher PSO forces than 2-rods (336 N) and 6-rods had lower PSO forces (324.2 N). 5- and 6-rods led to the lowest rod von Mises stresses across the PSO. 6-rod had the maximum factor of safety on the primary rods. CONCLUSIONS: In this finite element analysis, 4-rods reduced stresses on primary rods across a lumbar PSO. Although increased rigidity afforded by 5- and 6-rods decreased rod stresses, it resulted in less load transfer to the anterior vertebral column (particularly for 6-rod), which may not be favorable for the healing of the anterior column. A balance between the construct's rigidity and anterior load sharing is essential.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Análisis de Elementos Finitos , Osteotomía , Fenómenos Biomecánicos
4.
Global Spine J ; 13(8): 2336-2344, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35225035

RESUMEN

STUDY DESIGN: Finite element (FE) study. OBJECTIVE: Pedicle subtraction osteotomy (PSO) is a surgical method to correct sagittal plane deformities. In this study, we aimed to investigate the biomechanical effects of lumbar disc degeneration on the instrumentation following PSO and assess the effects of using interbody spacers adjacent to the PSO level in a long instrumented spinal construct. METHODS: A spinopelvic model (T10-pelvis) with PSO at the L3 level was used to generate 3 different simplified grades of degenerated lumbar discs (mild (Pfirrmann grade III), moderate (Pfirrmann grade IV), and severe (Pfirrmann grade V)). Instrumentation included eighteen pedicle screws and bilateral primary rods. To investigate the effect of interbody spacers, the model with normal disc height was modified to accommodate 2 interbody spacers adjacent to the PSO level through a lateral approach. For the models, the rods' stress distribution, PSO site force values, and the spine range of motion (ROM) were recorded. RESULTS: The mildly, moderately, and severely degenerated models indicated approximately 10%, 26%, and 40% decrease in flexion/extension motion, respectively. Supplementing the instrumented spinopelvic PSO model using interbody spacers reduced the ROM by 22%, 21%, 4%, and 11% in flexion, extension, lateral bending, and axial rotation, respectively. The FE results illustrated lower von Mises stress on the rods and higher forces at the PSO site at higher degeneration grades and while using the interbody spacers. CONCLUSIONS: Larger and less degenerated discs adjacent to the PSO site may warrant consideration for interbody cage instrumentation to decrease the risk of rod fracture and PSO site non-union.

5.
Eur Spine J ; 31(11): 3050-3059, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35932334

RESUMEN

PURPOSE: Multi-rod constructs are used commonly to stabilize pedicle subtraction osteotomies (PSO). This study aimed to evaluate biomechanical properties of different satellite rod configurations and effects of screw-type spanning a PSO. METHODS: A validated 3D spinopelvic finite element model with a L3 PSO (30°) was used to evaluate 5 models: (1) Control (T10-pelvis + 2 rods); (2) lateral satellite rods connected via offsets to monoaxial screws (LatSat-Mono) or (3) polyaxial screws (LatSat-Poly); (4) in-line satellite rods connected to monoaxial screws (InSat-Mono) or (4) polyaxial screws (InSat-Poly). Global and PSO range of motions (ROM) were recorded. Rods' von Mises stresses and PSO forces were recorded and the percent differences from Control were calculated. RESULTS: All satellite rods (save InSat-Mono) increased PSO ROM and decreased primary rods' von Mises stresses at the PSO. Lateral rods increased PSO forces (LatSat-Mono:347.1 N; LatSat-Poly:348.6 N; Control:336 N) and had relatively lower stresses, while in-line rods decreased PSO forces (InSat-Mono:280.1 N; InSat-Poly:330.7 N) and had relatively higher stresses. Relative to polyaxial screws, monoaxial screws further decreased PSO ROM, increased satellite rods' stresses, and decreased PSO forces for in-line rods, but did not change PSO forces for lateral rods. CONCLUSION: Multi-rod constructs using in-line and lateral satellite rods across a PSO reduced primary rods' stresses. Subtle differences in biomechanics suggest lateral satellite rods, irrespective of screw type, increase PSO forces and lower rod stresses compared to in-line satellite rods, which had a high degree of posterior instrumentation stress shielding and lower PSO forces. Clinical studies are warranted to determine if these findings influence clinical outcomes.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Tornillos Óseos , Fenómenos Biomecánicos , Rango del Movimiento Articular , Osteotomía , Vértebras Lumbares/cirugía
6.
Eur Spine J ; 31(4): 963-979, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35092449

RESUMEN

PURPOSE: Although distraction-based growing rods (GR) are the gold standard for the treatment of early onset scoliosis, they suffer from high failure rates. We have (1) performed a literature search to understand the deficiencies of the current protocols, (2) in vitro evaluation of GRs using our proposed protocol and performed a finite element (FE) model validation, and (3) identified key features which should be considered in mechanical testing setups. METHODS: PubMed, Embase, and Web of Science databases were searched for articles published on (a) in vivo animal, in vitro cadaveric, and biomechanical studies analyzing the use of GRs as well as (b) failure mechanisms and risk factors for GRs. Both FE and benchtop models of a proposed TGR test construct were developed and evaluated for two cases, long tandem connectors (LT), and side-by-side connectors (SBS). The test construct consisted of five polymer blocks representing vertebral bodies, joined with springs to simulate spinal stiffness. The superior and inferior blocks accepted the pedicle screw anchors, while the three middle blocks were floating. After the pedicle screws, rods, and connectors were assembled onto this construct, distraction was performed, mimicking scoliosis surgery. The resulting distracted constructs were then subjected to static compression-bending loading. Yield load and stiffness were calculated and used to verify/validate the FE results. RESULTS: From the literature search, key features identified as significant were axial and transverse connectors, contoured rods, and distraction, distraction being the most challenging feature to incorporate in testing. The in silico analyses, once they are validated, can be used as a complementing technique to investigate other anatomical features which are not possible in the mechanical setup (like growth/scoliosis curvature). Based on our experiment, the LT constructs showed higher stiffness and yield load compared to SBS (78.85 N/mm vs. 59.68 N/mm and 838.84 N vs. 623.3 N). The FE predictions were in agreement with the experimental outcomes (within 10% difference). The maximum von Mises stresses were predicted adjacent to the distraction site, consistent with the location of observed failures in vivo. CONCLUSION: The two-way approach presented in this study can lead to a robust prediction of the contributing factors to the in vivo failure.


Asunto(s)
Tornillos Pediculares , Escoliosis , Fusión Vertebral , Humanos , Escoliosis/cirugía , Fusión Vertebral/métodos , Columna Vertebral
7.
JOR Spine ; 3(3): e1119, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33015580

RESUMEN

OBJECTIVE: The emergence of distraction-based growing rods has provided the means to reduce the progression of spinal deformity in early onset scoliosis (EOS). The current protocols for evaluating spinal implants (ie, ASTM-F1717 and ISO-12189) were developed for fusion/dynamic devices. These protocols do not feature long unsupported rod lengths subjected to distraction. Due to the unsuitability of the existing guidelines for the evaluation of growing rods, a new distraction-based finite element protocol is presented herein for the first time. METHOD: A vertebrectomy (VO) model from current protocols was modified to accommodate multi-spinal segments (ie, MS model) in which springs with appropriate stiffness were simulated in between the plastic blocks. To assess the efficacy of the protocol, two different computational studies were conducted: (a) compression-bending (MS-CB) with no distraction, and (b) distraction followed by compression-bending (MS-D + CB). In each study, the model with no axial connector (rods-only) was modified to include a) 80-mm long tandem (LT) connectors, and b) side-by-side (SBS) connectors. Stiffness and yield loads were calculated as per ASTM-F1717 guidelines and compared with the corresponding VO models with no distraction. In the MS-D + CB models, distraction was applied at the top block, stretching the spring-block construct in a simulation of scoliosis surgery prior to locking the construct at the connector-rods' interface. RESULTS: MS-CB models predicted higher stiffness and yield loads, compared to the VO models. The locking mechanism produced pre-existing stresses on the rod-connector interface, which caused a shift in the location of high-stress regions to the distraction site. Distraction led to a decrease in the construct's stiffness and yield load. DISCUSSION: The proposed protocol enables the simulation of clinical parameters that are not feasible in the F1717 models and predicted stress patterns in the hardware consistent with observed clinical failures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...